Thermal Evaporation Coating System (For BeSearch)

BACK

Thermal Evaporation Coating System (For BeSearch)


The equipment adopts an integrated design with the main unit and control system combined, and can also be integrated with a glovebox.


CONTACT US

Basic Configuration & Functions

No.

Basic Configuration

Main Parameters & Functions

-

Evaporation Source: Boat Source

Capacity: 1–3CC, Tungsten wire + AlN/Al₂O₃.

-

Evaporation Source: Beam Source

Capacity: 5, 10CC, Tantalum wire + Al₂O₃/PBN crucible; Temperature range: RT–500°C, Accuracy: ±1°C.

1

Film Thickness System

Inficon SQC–310 Film Thickness Monitor + 2 sets of crystal oscillation probes, Rate accuracy: 0.1 Å/s, Thickness accuracy: 1 Å.

2

Substrate Stage

Max substrate size: 300mm×300mm, with rotation function; Equipped with heating or water cooling (optional).

3

Vacuum System

Turbo pump + mechanical pump with bypass pumping system, chamber venting without stopping main pump (cryopump optional).

4

Control System

PLC+PC or PLC+touch screen for automatic program operation. Includes one-click pumping and venting functions, and misoperation interlock protection.

5

Glovebox

(Optional) Connectable to the coating equipment for substrate handling in water-free and oxygen-free environment.

6

Sample Chamber

(Optional) Vacuum robot for substrate loading/unloading without breaking process vacuum.

✔ Substrate Sizes Available: 100×100mm, 210×210mm, 300×300mm, etc.; Suitable for evaporation coating of medium-low temperature metals (Ag, Au, Al, In, etc.), compounds (LiF, SnO) and organic materials.

Equipment Introduction - Test Data

Evaporation source during heating
Evaporation source during heating
Rate stability
Rate stability
Substrate uniformity
Substrate Uniformity: < 5% on the diagonal of 300×300mm substrate

Basic Configuration & Functions
Max substrate size: 300×300mm; Suitable for depositing medium-high temperature metals (Ti, Ni, Ag, etc.) and oxides (SiO₂, Al₂O₃, etc.) thin films.

Internal structure of chamber
Internal structure of chamber
Internal view of vacuum chamber
Internal view of vacuum chamber
Electron beam evaporation source
Electron beam evaporation source
Thermal resistance evaporation source
Thermal resistance evaporation source
Heated substrate holder
Heated substrate holder
×放大的图片

Basic Configuration & Functions

Basic Configuration

Main Parameters & Functions

Electron Beam Source

Imported e-gun with 4 or 6 pockets, rotary switching. Film thickness uniformity >95%.

Thermal Evaporation Source

Single or multiple thermal evaporation sources (boat or crucible), DC power supply. Film thickness uniformity >95%.

Vacuum System

Turbo pump + mechanical pump with bypass pumping system. Chamber venting without stopping main pump (cryopump optional).

Control System

PLC+PC or PLC+touch screen, automatic program control. Film thickness controller enables automatic evaporation rate control.

Glovebox

(Optional) Integrated with coater for substrate handling in water-free and oxygen-free environment.

Sample Chamber

(Optional) Vacuum robot for substrate loading/unloading without breaking process vacuum.

In addition to the main e-beam coater, a glovebox and sample chamber can be configured to enable substrate handling in nitrogen or vacuum environment.